Specialty-Focused PGx Panels That Providers Actually Order

Five targeted gene panels in liquid format — run the samples you have today, on the PCR instruments you already own.

Five MarinaBioLab PGx gene detection kit boxes displayed in a molecular laboratory

Focused Panels, Not 200-Gene Reports

Each panel answers one prescribing question, so providers get a result they act on instead of a report they set aside.

Liquid Format, No Batch Minimums

Run the samples in front of you and store the rest — no waiting to fill a plate, no discarding unused wells.

Runs on Instruments You Already Own

Works on 99% of PCR instruments.

Available PGx Panels

All panels: 20 tests/kit · buccal swab specimen · PCR-fluorescence probe method

Why Labs Choose Targeted PGx

Broad PGx panels create a reporting problem. A cardiologist ordering a clopidogrel workup does not need 200 genes, and long reports get filed instead of used — which means no repeat orders. Our panels are built the other way around. Each kit covers the genes tied to one drug class and one specialty, so the report is short enough to read at the point of prescribing.

The reagents ship in liquid format, so your lab controls the economics. Run four samples on Monday and store the rest of the kit for next week. No batch minimums, no plates thrown away because you never hit volume.

Technical Assurance — Performance You Can Verify

Analytical sensitivity: Detects the target polymorphism from 1 ng of input DNA (MTHFR panel: 200 copies/µL).

Reproducibility: Ct coefficient of variation ≤ 5% across 10 replicate detections of reference material.

Internal control on every reaction: A ROX-channel internal standard runs alongside each sample to flag extraction failure or inhibition before you report a result.

Carryover contamination control: Uracil-DNA glycosylase is built into every PCR mix, with a 37 °C digestion step ahead of amplification.

Unambiguous genotype calls: Dual FAM/VIC allele discrimination resolves wild-type, heterozygous, and homozygous mutant from a single reaction, with a Ct < 38 call threshold.

Non-invasive collection: Buccal swab specimens — no phlebotomy, no cold-chain blood draw to coordinate.

Defined controls in every kit: Weakly positive and blank controls included, with published acceptance criteria (control Ct ≤ 32).

Access the IFU for each panel — including full thermal protocols, instrument settings, and interpretation tables — via the Documentation Portal (email gate).

Package & Use Details

Format

Liquid, single-tube PCR mixes (real-time PCR, fluorescence probe method)

Pack size

20 tests/kit

Specimen

Human buccal swab; genomic DNA at 5–15 ng/µL, A260/A280 of 1.8–2.0

Reaction volume

12.5 µL (11.5 µL PCR mix + 1 µL template)

Instruments

Works on 99% of PCR instruments.

Run time

Approximately 65–90 minutes, panel and instrument dependent

Storage

−20 ± 5 °C, protected from light; 1-year shelf life; fewer than 6 freeze-thaw cycles

Documentation Portal

Panel Instructions for Use

Access the IFU for each panel, including full thermal protocols, instrument settings, and interpretation tables.

Enter your email to view all five IFUs

Your access request is recorded so MarinaBioLab can support documentation and product questions.

Ready to add PGx without adding instruments or waste?

Request a quote and see how targeted panels in liquid format let your lab start reporting PGx at the volume you actually have.